| Fiberglass Batt or Blanket |
Approximately R-2.9 to R-3.8 |
Low by itself; requires careful fitting and separate air-sealing |
Vapor permeability varies by facing; loses effectiveness when compressed or wet |
Noncombustible glass fibers, but facings and binders may burn |
Installed between rafters or roof framing members |
Widely available, lightweight, relatively easy to install, and suitable for standard framing |
Leaves gaps around wiring and penetrations; does not stop air leakage without additional detailing |
Budget-conscious projects with regular, accessible roof framing |
| Blown-In Cellulose |
Approximately R-3.2 to R-3.8 |
Moderate; performs best when combined with a dedicated air barrier |
Hygroscopic and can absorb moisture; requires moisture control and proper density |
Typically treated with fire retardants; must be protected from persistent leaks |
Blown into enclosed roof cavities or installed as dense-pack insulation |
Uses a high proportion of recycled paper fiber and fills irregular spaces effectively |
Can settle if improperly installed; not suitable for damp cavities or areas with ongoing roof leaks |
Retrofits where cavities are enclosed and sustainability is a priority |
| Mineral Wool Batt or Board |
Approximately R-3.0 to R-3.3 |
Low to moderate; separate air-sealing is normally needed |
Water-resistant and vapor-permeable; does not readily absorb liquid water |
Noncombustible and maintains strong fire resistance at high temperatures |
Installed between rafters or as continuous rigid boards above or below the roof deck |
Excellent fire resistance, good sound control, and strong dimensional stability |
Heavier and often more difficult to cut and handle than fiberglass |
Roofs where fire resistance, acoustics, and durability are important |
| Expanded Polystyrene (EPS) |
Approximately R-3.6 to R-4.2 |
Moderate as a continuous layer; joints and edges must be sealed |
Moisture-resistant but vapor-permeable compared with many other rigid foams |
Combustible; requires approved protective coverings and assembly detailing |
Installed as rigid boards above or below the roof deck |
Lightweight, cost-effective, and available in different densities and thicknesses |
Lower R-value per inch than some other rigid foams; vulnerable to solvents and physical damage |
Continuous insulation where moderate thermal performance and vapor drying are desired |
| Extruded Polystyrene (XPS) |
Approximately R-4.5 to R-5.0 |
Moderate to high when installed continuously with sealed joints |
Low vapor permeability and high moisture resistance; can limit drying potential |
Combustible; normally requires a code-approved thermal or ignition barrier |
Installed as rigid boards above or below the roof deck |
Good moisture resistance, compressive strength, and consistent board performance |
Lower vapor permeability can trap moisture if the roof assembly is not properly designed |
Roof assemblies requiring durable rigid boards and strong moisture resistance |
| Polyisocyanurate (Polyiso) |
Approximately R-5.6 to R-6.5 at common temperatures; performance decreases in cold conditions |
High when installed as a continuous layer with taped or sealed joints |
Low vapor permeability; foil-faced products can act as vapor retarders when joints are sealed |
Combustible foam core; fire performance depends on facers and the complete roof assembly |
Installed primarily as continuous rigid insulation above the roof deck |
High R-value per inch and effective reduction of thermal bridging through rafters |
Cold-weather R-value can be lower than its labeled value; boards must be protected and carefully detailed |
High-performance roofs with limited space for insulation thickness |
| Open-Cell Spray Polyurethane Foam |
Approximately R-3.5 to R-3.7 |
High when applied continuously and fully adhered to the roof deck |
Air-sealing material but vapor-permeable; may require a separate vapor-control layer in some climates |
Combustible; generally requires an approved ignition or thermal barrier |
Sprayed directly to the underside of the roof deck by trained installers |
Expands into irregular spaces, reduces air leakage, and uses less material per inch than closed-cell foam |
Lower R-value per inch, absorbs more water vapor than closed-cell foam, and is sensitive to installation quality |
Complex roof shapes where air sealing is more important than maximum R-value per inch |
| Closed-Cell Spray Polyurethane Foam |
Approximately R-6.0 to R-7.0 |
Very high when properly applied; functions as both insulation and an air barrier |
Low vapor permeability and strong resistance to water intrusion; can restrict roof-deck drying |
Combustible; requires code-compliant protective coverings or approved assembly protection |
Sprayed directly to the underside of the roof deck or into enclosed cavities |
Highest R-value per inch among common spray-foam options, adds structural rigidity, and limits air and moisture movement |
Higher material cost, difficult removal, strict installation requirements, and potential moisture-trapping risk |
High-performance roofs with limited cavity depth or major air-leakage problems |